¡á Comparison : PHE vs Shell & Tube HE
Plate heat exchanger vs Shell & Tuge heat exchanger
  Traditional PHE Shell & Tube heat exchanger
Temperature cross possible Impossible
Temperature approach 1¡É(2 ¡ÆF) 5¡É(10 ¡ÆF)
Multiple duty Possible Impossible
Piping connections From one direction
(on frame plate)
From several direction
Heat transfer ratio 3 - 5 1
Operating weight ratio 1 3 - 10
Hold - up volume Low High
Space ratio 1 2 - 5
Welds None Welded
Sensitivity to vibrations Not sensitive Sensitive
Gaskets On every plate On each bonnet
Detection of leakage Easy to detect on exterior Difficult to detect
Access for inspection On each side of plate Limited
Time required for opening 15 minutes
(with pneumatic tightener)
60 - 90 minutes
Repair Easy to replace plate
and/or gasket
Requires tube plugging
= decreasde capacity
Modification Easy by adding or
removing plates
Impossible

 